| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| An unauthenticated remote code execution vulnerability exists in Remote for Mac, a macOS remote control utility developed by Aexol Studio, in versions up to and including 2025.7. When the application is configured with authentication disabled (i.e., the "Allow unknown devices" option is enabled), the /api/executeScript endpoint is exposed without access control. This allows unauthenticated remote attackers to inject arbitrary AppleScript payloads via the X-Script HTTP header, resulting in code execution using do shell script. Successful exploitation grants attackers the ability to run arbitrary commands on the macOS host with the privileges of the Remote for Mac background process. |
| WF2220 exposes endpoint /cgi-bin-igd/netcore_get.cgi that returns configuration of the device to unauthorized users. Returned configuration includes cleartext password.
The vendor was contacted early about this disclosure but did not respond in any way. |
| Endpoint /cgi-bin-igd/netcore_set.cgi which is used for changing device configuration is accessible without authentication. This poses a significant security threat allowing for e.g: administrator account hijacking or AP password changing.
The vendor was contacted early about this disclosure but did not respond in any way. |
| The
“socket” module provides a pure-Python fallback to the
socket.socketpair() function for platforms that don’t support AF_UNIX,
such as Windows. This pure-Python implementation uses AF_INET or
AF_INET6 to create a local connected pair of sockets. The connection
between the two sockets was not verified before passing the two sockets
back to the user, which leaves the server socket vulnerable to a
connection race from a malicious local peer.
Platforms that support AF_UNIX such as Linux and macOS are not affected by this vulnerability. Versions prior to CPython 3.5 are not affected due to the vulnerable API not being included. |
| The exos 9300 application can be used to configure Access Managers (e.g. 92xx, 9230 and 9290). The configuration is done in a graphical user interface on the dormakaba exos server. As soon as the save button is clicked in exos 9300, the whole configuration is sent to the selected Access Manager via SOAP. The SOAP request is sent without any prior authentication or authorization by default. Though authentication and authorization can be configured using IPsec for 92xx-K5 devices and mTLS for 92xx-K7 devices, it is not enabled by default and must therefore be activated with additional steps.
This insecure default allows an attacker with network level access to completely control the whole environment. An attacker is for example easily able to conduct the following tasks without prior authentication:
- Re-configure Access Managers (e.g. remove alarming system requirements)
- Freely re-configure the inputs and outputs
- Open all connected doors permanently
- Open all doors for a defined time interval
- Change the admin password
- and many more
Network level access can be gained due to an insufficient network segmentation as well as missing LAN firewalls. Devices with an insecure configuration have been identified to be directly exposed to the internet. |
| The embedded web server lacks authentication and access controls, allowing unrestricted remote access. This could lead to configuration changes, operational disruption, or arbitrary code execution depending on the environment and exposed functionality. |
| CVE-2025-1701 is a high-severity vulnerability in the MIM Admin service. An attacker could exploit this vulnerability by sending a specially crafted request over the RMI interface to execute arbitrary code with the privileges of the MIM Admin service. The RMI interface is only accessible locally (listening on 127.0.0.1), limiting the attack vector to the local machine. This means that in a properly configured hospital environment, an attacker must have already compromised the network and additionally compromised the system where the MIM Admin service is running. From there, attackers with sufficient knowledge of MIM's implementation, library usage, and functionality with access to extend the MIM RMI library could force the MIM Admin service to run commands on the local machine with its privileges.
Users of MIM Software products exposed via RDP or multi-user application virtualization system should take note that the system being exposed is the environment hosting the virtualized MIM client.
This issue affects MIM Admin Service: before 7.2.13, 7.3.8, 7.4.3 |
| A vulnerability allows unauthorized access to functionality inadequately constrained by ACLs. Attackers may exploit this to unauthenticated execute commands potentially leading to unauthorized data manipulation, access to privileged functions, or even the execution of arbitrary code. |
| An unauthenticated remote attacker can access a URL which causes the device to reboot. |
| General Industrial Controls Lynx+ Gateway
is missing critical authentication in the embedded web server which could allow an attacker to remotely reset the device. |
| Improper control of framework service permissions with possibility of some sensitive device information leakage. |
| The vulnerability allows an attacker to bypass the authentication requirements for a specific PAM endpoint. |
| Uniweb/SoliPACS WebServer developed by EBM Technologies has a Missing Authentication vulnerability, allowing unauthenticated remote attackers to access a specific page to obtain user group names. |
| Uniweb/SoliPACS WebServer developed by EBM Technologies has a Missing Authentication vulnerability, allowing unauthenticated remote attackers to access a specific page to obtain information such as account names and IP addresses. |
| Improper authentication vulnerability in exists in multiple printers and scanners which implement Web Based Management provided by BROTHER INDUSTRIES, LTD. If this vulnerability is exploited, a network-adjacent user who can access the product may impersonate an administrative user. As for the details of affected product names, model numbers, and versions, refer to the information provided by the respective vendors listed under [References]. |
| An unauthenticated attacker can reset the board and stop transmitter
operations by sending a specially-crafted GET request to the command.cgi
gateway, resulting in a denial-of-service scenario. |
| Delta Electronics DIAView has an authentication bypass vulnerability. |
| An unauthenticated remote attacker can cause a Denial of Service by turning off the output of the UPS via Modbus command. |
| An unauthenticated remote attacker can gain full access on the affected devices as they are shipped without a password by default and setting one is not enforced. |
| An unauthenticated remote attacker could potentially disrupt operations by switching between multiple configuration presets via Modbus (TCP). |