| An issue in almando GmbH Almando Play APP (com.almando.play) 1.8.2 allows a remote attacker to obtain sensitive information via the firmware update process |
| Synaccess netBooter NP-02x/NP-08x 6.8 contains an authentication bypass vulnerability in the webNewAcct.cgi script that allows unauthenticated attackers to create admin user accounts. Attackers can exploit the missing control check by sending crafted POST requests to create administrative accounts and gain unauthorized control over power supply management. |
| A vulnerability has been discovered in AC Smart II where passwords can be changed without authorization. This page contains a hidden form for resetting the administrator password. The attacker can manipulate the page using developer tools to display and use the form. This form allows you to change the administrator password without verifying login status or user permissions. |
| COMMAX Smart Home System allows an unauthenticated attacker to change configuration and cause denial-of-service through the setconf endpoint. Attackers can trigger a denial-of-service scenario by sending a malformed request to the setconf endpoint. |
| Missing authentication for critical function vulnerability exists in Rakuten Turbo 5G firmware version V1.3.18 and earlier. If this vulnerability is exploited, a remote unauthenticated attacker may update or downgrade the firmware on the device. |
| OPW Fuel Management Systems SiteSentinel
could allow an attacker to bypass authentication to the server and obtain full admin privileges. |
| General Industrial Controls Lynx+ Gateway
is missing critical authentication in the embedded web server which could allow an attacker to remotely reset the device. |
| Seeyon Zhiyuan OA Web Application System versions up to and including 7.0 SP1 improperly decode and parse the `enc` parameter in thirdpartyController.do. The decoded map values can influence session attributes without sufficient authentication/authorization checks, enabling attackers to assign a session to arbitrary user IDs. VulnCheck has observed this vulnerability being exploited in the wild as of 2025-10-30 at 00:30:40.855917 UTC. |
| An issue was discovered on Marbella KR8s Dashcam FF 2.0.8 devices. Via port 7777 without any need to pair or press a physical button, a remote attacker can disable recording, delete recordings, or even disable battery protection to cause a flat battery to essentially disable the car from being used. During the process of changing these settings, there are no indications or sounds on the dashcam to alert the dashcam owner that someone else is making those changes. |
| The vulnerability allows unauthenticated users to download a file containing session ID data by directly accessing the "/cgi-bin/CliniNET.prd/utils/userlogxls.pl" endpoint. |
| The administrative interface listens by default on all interfaces on a TCP port and does not require authentication when being accessed. |
| An issue in Plug n Play Camera com.ezset.delaney 1.2.0 allows a remote attacker to obtain sensitive information via the firmware update process. |
| The ISOinsight from Netvision has a Missing Authentication vulnerability, allowing unauthenticated remote attackers to access certain system functions. These functions include viewing the administrator list, viewing and editing IP settings, and uploading files. |
| The software tools used by service personnel to test & calibrate the ventilator do not support user authentication. An attacker with access to the Service PC where the tools are installed could obtain diagnostic information through the test tool or manipulate the ventilator's settings and embedded software via the calibration tool, without having to authenticate to either tool. This could result in unauthorized disclosure of information and/or have unintended impacts on device settings and performance. |
| The
“socket” module provides a pure-Python fallback to the
socket.socketpair() function for platforms that don’t support AF_UNIX,
such as Windows. This pure-Python implementation uses AF_INET or
AF_INET6 to create a local connected pair of sockets. The connection
between the two sockets was not verified before passing the two sockets
back to the user, which leaves the server socket vulnerable to a
connection race from a malicious local peer.
Platforms that support AF_UNIX such as Linux and macOS are not affected by this vulnerability. Versions prior to CPython 3.5 are not affected due to the vulnerable API not being included. |
| Instantel Micromate lacks authentication on a configuration port which could allow an attacker to execute commands if connected. |
| The iSTAR door controllers running firmware prior to version 6.6.B, does not support authenticated
communications with ICU, which may allow an attacker to gain unauthorized access |
| Uniweb/SoliPACS WebServer developed by EBM Technologies has a Missing Authentication vulnerability, allowing unauthenticated remote attackers to access a specific page to obtain user group names. |
| Uniweb/SoliPACS WebServer developed by EBM Technologies has a Missing Authentication vulnerability, allowing unauthenticated remote attackers to access a specific page to obtain information such as account names and IP addresses. |
| The affected product allows unauthenticated access to Real Time Streaming Protocol (RTSP) services, which may allow an attacker unauthorized access to camera configuration information. |