Export limit exceeded: 424397 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.

Search

Search Results (4527 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2025-36751 1 Growatt 2 Mic3300tl-x, Shinelan-x 2026-04-15 N/A
Encryption is missing on the configuration interface for Growatt ShineLan-X and MIC 3300TL-X. This allows an attacker with access to the network to intercept and potentially manipulate communication requests between the inverter and its cloud endpoint.
CVE-2025-66266 1 Megatec 1 Upsilon2000 2026-04-15 N/A
The RupsMon.exe service executable in UPSilon 2000 has insecure permissions, allowing the 'Everyone' group Full Control. A local attacker can replace the executable with a malicious binary to execute code with SYSTEM privileges or simply change the config path of the service to a command; starting and stopping the service to immediately achieve code execution and privilege escalation
CVE-2025-62691 2 Intercom, Microsoft 2 Malion, Windows 2026-04-15 N/A
Security Point (Windows) of MaLion and MaLionCloud contains a stack-based buffer overflow vulnerability in processing HTTP headers. Receiving a specially crafted request from a remote unauthenticated attacker could lead to arbitrary code execution with SYSTEM privilege.
CVE-2025-7916 1 Simopro Technology 1 Winmatrix3 2026-04-15 9.8 Critical
WinMatrix3 developed by Simopro Technology has an Insecure Deserialization vulnerability, allowing unauthenticated remote attackers to execute arbitrary code on the server by sending maliciously crafted serialized contents.
CVE-2025-7921 2026-04-15 9.8 Critical
Certain modem models developed by Askey has a Stack-based Buffer Overflow vulnerability, allowing unauthenticated remote attackers to control the program's execution flow and potentially execute arbitrary code.
CVE-2025-14346 2026-04-15 9.8 Critical
WHILL Model C2 Electric Wheelchairs and Model F Power Chairs do not enforce authentication for Bluetooth connections. An attacker within range can pair with the device and issue movement commands, override speed restrictions, and manipulate configuration profiles without any credentials or user interaction.
CVE-2024-10456 1 Deltaww 1 Infrasuite Device Master 2026-04-15 9.8 Critical
Delta Electronics InfraSuite Device Master versions prior to 1.0.12 are affected by a deserialization vulnerability that targets the Device-Gateway, which could allow deserialization of arbitrary .NET objects prior to authentication.
CVE-2025-64693 2 Intercom, Microsoft 2 Malion, Windows 2026-04-15 N/A
Security Point (Windows) of MaLion and MaLionCloud contains a heap-based buffer overflow vulnerability in processing Content-Length. Receiving a specially crafted request from a remote unauthenticated attacker could lead to arbitrary code execution with SYSTEM privilege.
CVE-2024-7395 1 Korenix 1 Jetport 5601 2026-04-15 N/A
An authentication bypass vulnerability in Korenix JetPort 5601v3 allows an attacker to access functionality on the device without specifying a password.This issue affects JetPort 5601v3: through 1.2.
CVE-2025-30057 1 Cgm 1 Clininet 2026-04-15 N/A
In UHCRTFDoc, the filename parameter can be exploited to execute arbitrary code via command injection into the system() call in the ConvertToPDF function.
CVE-2024-43653 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability  allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2025-1302 2026-04-15 9.8 Critical
Versions of the package jsonpath-plus before 10.3.0 are vulnerable to Remote Code Execution (RCE) due to improper input sanitization. An attacker can execute aribitrary code on the system by exploiting the unsafe default usage of eval='safe' mode. **Note:** This is caused by an incomplete fix for [CVE-2024-21534](https://security.snyk.io/vuln/SNYK-JS-JSONPATHPLUS-7945884).
CVE-2025-3114 2026-04-15 N/A
Code Execution via Malicious Files: Attackers can create specially crafted files with embedded code that may execute without adequate security validation, potentially leading to system compromise. Sandbox Bypass Vulnerability: A flaw in the TERR security mechanism allows attackers to bypass sandbox restrictions, enabling the execution of untrusted code without appropriate controls.
CVE-2025-26692 2026-04-15 N/A
Quick Agent V3 and Quick Agent V2 contain an issue with improper limitation of a pathname to a restricted directory ('Path Traversal'). If exploited, arbitrary code may be executed by a remote unauthenticated attacker with the Windows system privilege where the product is running.
CVE-2024-6981 1 Omntec 1 Proteus Tank Monitoring 2026-04-15 9.8 Critical
OMNTEC Proteus Tank Monitoring OEL8000III Series could allow an attacker to perform administrative actions without proper authentication.
CVE-2025-6560 2026-04-15 9.8 Critical
Multiple wireless router models from Sapido have an Exposure of Sensitive Information vulnerability, allowing unauthenticated remote attackers to directly access a system configuration file and obtain plaintext administrator credentials.  The affected models are out of support; replacing the device is recommended.
CVE-2025-27720 2026-04-15 7.4 High
The Pixmeo Osirix MD Web Portal sends credential information without encryption, which could allow an attacker to steal credentials.
CVE-2025-30519 1 Doverfuelingsolutions 1 Progauge Maglink Lx Console 2026-04-15 9.8 Critical
Dover Fueling Solutions ProGauge MagLink LX4 Devices have default root credentials that cannot be changed through standard administrative means. An attacker with network access to the device can gain administrative access to the system.
CVE-2024-7205 1 Coolkit 1 Ewelink 2026-04-15 N/A
When the device is shared, the homepage module are before 2.19.0  in eWeLink Cloud Service allows Secondary user to take over devices as primary user via sharing unnecessary device-sensitive information.
CVE-2023-7304 1 Ruijie 1 Rg-uac 2026-04-15 N/A
Ruijie RG-UAC Application Management Gateway contains a command injection vulnerability via the 'nmc_sync.php' interface. An unauthenticated attacker able to reach the affected endpoint can inject shell commands via crafted request data, causing the application to execute arbitrary commands on the host. Successful exploitation can yield full control of the application process and may lead to system-level access depending on the service privileges. VulnCheck has observed this vulnerability being targeted by the RondoDox botnet campaign.