Search Results (4527 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2025-59091 1 Dormakaba 1 Kaba Exos 9300 2026-04-15 N/A
Multiple hardcoded credentials have been identified, which are allowed to sign-in to the exos 9300 datapoint server running on port 1004 and 1005. This server is used for relaying status information from and to the Access Managers. This information, among other things, is used to graphically visualize open doors and alerts. However, controlling the Access Managers via this interface is also possible. To send and receive status information, authentication is necessary. The Kaba exos 9300 application contains hard-coded credentials for four different users, which are allowed to login to the datapoint server and receive as well as send information, including commands to open arbitrary doors.
CVE-2025-24325 2 Intel, Linux 2 Ethernet 800 Series Software, Linux Kernel 2026-04-15 8.8 High
Improper input validation in the Linux kernel-mode driver for some Intel(R) 800 Series Ethernet before version 1.17.2 may allow an authenticated user to potentially enable escalation of privilege via local access.
CVE-2024-43649 2026-04-15 8.8 High
Authenticated command injection in the filename of a <redacted>.exe request leads to remote code execution as the root user. This issue affects Iocharger firmware for AC models before version 24120701. Likelihood: Moderate – This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all <redacted> fields. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a payload. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: This attack can be performed over any network conenction serving the web interfacr (AV:N), and there are not additional mitigating measures that need to be circumvented (AC:L) or other prerequisites (AT:N). The attack does require privileges, but the level does not matter (PR:L), there is no user interaction required (UI:N). The attack leeds to a full compromised of the charger (VC:H/VI:H/VA:H) and a compromised charger can be used to "pivot" to networks that should normally not be reachable (SC:L/SI:L/SA:H). Because this is an EV chargers with significant pwoer, there is a potential safety imp0act (S:P). THis attack can be automated (AU:Y).
CVE-2024-43650 2026-04-15 N/A
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root This issue affects  firmware versions before 24120701. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: The attack can be executed over any network connection serving the web interface (AV:N). There are no additional measures that need to be circumvented (AC:L) or attack preconditions (AT:N). THe attack is privileged, but the level does not matter (PR:L) and does not require user interaction (UI:N). Attack leads to full system compromised (VC:H/VI:H/VA:H) and compromised devices can be used to "pivot" to other networks that should be unreachable (SC:L/SI:L/SA:H). Because this an EV charger using high power, there is a potential safety impact (S:P). The attack can be automated (AU:Y).
CVE-2024-43651 2026-04-15 N/A
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC models before version 241207101 Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network connection serving the web interface is vulnerable (AV:N) and there are no additional measures to circumvent (AC:L) nor does the attack require special conditions to be present (AT:N). The attack requires authentication, but the level does not matter (PR:L), nor is user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H) and a compromised device can be used to potentially "pivot" into a network that should nopt be reachable (SC:L/SI:L/SA:H). Because this is an EV charger handing significant power, there is a potential safety impact (S:P). THe attack can be autometed (AU:Y).
CVE-2024-43654 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root This issue affects all Iocharger AC EV charger models on a firmware version before 25010801. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2024-43657 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: High. However, the attacker will need a (low privilege) account to gain access to the action.exe CGI binary and upload the crafted firmware file, or convince a user with such access to upload it. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2025-59097 1 Dormakaba 1 Access Manager 2026-04-15 N/A
The exos 9300 application can be used to configure Access Managers (e.g. 92xx, 9230 and 9290). The configuration is done in a graphical user interface on the dormakaba exos server. As soon as the save button is clicked in exos 9300, the whole configuration is sent to the selected Access Manager via SOAP. The SOAP request is sent without any prior authentication or authorization by default. Though authentication and authorization can be configured using IPsec for 92xx-K5 devices and mTLS for 92xx-K7 devices, it is not enabled by default and must therefore be activated with additional steps. This insecure default allows an attacker with network level access to completely control the whole environment. An attacker is for example easily able to conduct the following tasks without prior authentication: - Re-configure Access Managers (e.g. remove alarming system requirements) - Freely re-configure the inputs and outputs - Open all connected doors permanently - Open all doors for a defined time interval - Change the admin password - and many more Network level access can be gained due to an insufficient network segmentation as well as missing LAN firewalls. Devices with an insecure configuration have been identified to be directly exposed to the internet.
CVE-2025-3463 2026-04-15 N/A
"This issue is limited to motherboards and does not affect laptops, desktop computers, or other endpoints." An insufficient validation vulnerability in ASUS DriverHub may allow untrusted sources to affect system behavior via crafted HTTP requests. Refer to the 'Security Update for ASUS DriverHub' section on the ASUS Security Advisory for more information.
CVE-2025-3621 2026-04-15 9.6 Critical
Vulnerabilities* in ActADUR local server product, developed and maintained by ProTNS, allows Remote Code Inclusion on host systems.  * vulnerabilities: * Improper Neutralization of Special Elements used in a Command ('Command Injection') * Use of Hard-coded Credentials * Improper Authentication * Binding to an Unrestricted IP Address The vulnerability has been rated as critical.This issue affects ActADUR: from v2.0.1.9 before v2.0.2.0., hence updating to version v2.0.2.0. or above is required.
CVE-2025-3714 2026-04-15 9.8 Critical
The LCD KVM over IP Switch CL5708IM has a Stack-based Buffer Overflow vulnerability in firmware versions prior to v2.2.215, allowing unauthenticated remote attackers to exploit this vulnerability to execute arbitrary code on the device.
CVE-2025-7353 1 Rockwellautomation 1 Controllogix 2026-04-15 N/A
A security issue exists due to the web-based debugger agent enabled on Rockwell Automation ControlLogix® Ethernet Modules. If a specific IP address is used to connect to the WDB agent, it can allow remote attackers to perform memory dumps, modify memory, and control execution flow.
CVE-2025-13828 1 Mautic 1 Mautic 2026-04-15 N/A
SummaryA non privileged user can install and remove arbitrary packages via composer for a composer based installed, even if the flag in update settings for enable composer based update is unticked. ImpactA low-privileged user of the platform can install malicious code to obtain higher privileges.
CVE-2024-36455 1 Broadcom 1 Symantec Privileged Access Management 2026-04-15 N/A
An improper input validation allows an unauthenticated attacker to achieve remote command execution on the affected PAM system by sending a specially crafted HTTP request.
CVE-2024-36456 1 Broadcom 1 Symantec Privileged Access Management 2026-04-15 N/A
This vulnerability allows an unauthenticated attacker to achieve remote command execution on the affected PAM system by uploading a specially crafted PAM upgrade file.
CVE-2024-37998 2026-04-15 9.8 Critical
A vulnerability has been identified in CPCI85 Central Processing/Communication (All versions < V5.40), SICORE Base system (All versions < V1.4.0). The password of administrative accounts of the affected applications can be reset without requiring the knowledge of the current password, given the auto login is enabled. This could allow an unauthorized attacker to obtain administrative access of the affected applications.
CVE-2025-43879 2026-04-15 N/A
WRH-733GBK and WRH-733GWH contain an improper neutralization of special elements used in an OS command ('OS Command Injection') vulnerability in the telnet function. If a remote unauthenticated attacker sends a specially crafted request to the affected product, an arbitrary OS command may be executed.
CVE-2025-61774 1 Pyvista 1 Pyvista 2026-04-15 N/A
PyVista provides 3D plotting and mesh analysis through an interface for the Visualization Toolkit (VTK). Version 0.46.3 of the PyVista Project is vulnerable to remote code execution via dependency confusion. Two pieces of code use`--extra-index-url`. But when `--extra-index-url` is used, pip always checks for the PyPI index first, and then the external index. One package listed in the code is not published in PyPI. If an attacker publishes a package with higher version in PyPI, the malicious code from the attacker controlled package may be pulled, leading to remote code execution and a supply chain attack. As of time of publication, a patched version is unavailable.
CVE-2025-61928 1 Better-auth 1 Better Auth 2026-04-15 N/A
Better Auth is an authentication and authorization library for TypeScript. In versions prior to 1.3.26, unauthenticated attackers can create or modify API keys for any user by passing that user's id in the request body to the `api/auth/api-key/create` route. `session?.user ?? (authRequired ? null : { id: ctx.body.userId })`. When no session exists but `userId` is present in the request body, `authRequired` becomes false and the user object is set to the attacker-controlled ID. Server-only field validation only executes when `authRequired` is true (lines 280-295), allowing attackers to set privileged fields. No additional authentication occurs before the database operation, so the malicious payload is accepted. The same pattern exists in the update endpoint. This is a critical authentication bypass enabling full an unauthenticated attacker can generate an API key for any user and immediately gain complete authenticated access. This allows the attacker to perform any action as the victim user using the api key, potentially compromise the user data and the application depending on the victim's privileges. Version 1.3.26 contains a patch for the issue.
CVE-2024-6060 1 Phloc 1 Webscopes 2026-04-15 N/A
An information disclosure vulnerability in Phloc Webscopes 7.0.0 allows local attackers with access to the log files to view logged HTTP requests that contain user passwords or other sensitive information.