Search Results (1943 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2024-28751 1 Ifm 2 Smart Plc Ac14xx Firmware, Smart Plc Ac4xxs Firmware 2026-04-15 9.1 Critical
An high privileged remote attacker can enable telnet access that accepts hardcoded credentials.
CVE-2025-23179 2026-04-15 5.5 Medium
CWE-798: Use of Hard-coded Credentials
CVE-2025-30125 1 Marbella 1 Kr8s Dashcam 2026-04-15 9.8 Critical
An issue was discovered on Marbella KR8s Dashcam FF 2.0.8 devices. All dashcams were shipped with the same default credentials of 12345678, which creates an insecure-by-default condition. For users who change their passwords, it's limited to 8 characters. These short passwords can be cracked in 8 hours via low-end commercial cloud resources.
CVE-2018-25126 1 Tvt 1 Nvms-9000 Firmware 2026-04-15 N/A
Shenzhen TVT Digital Technology Co., Ltd. NVMS-9000 firmware (used by many white-labeled DVR/NVR/IPC products) contains hardcoded API credentials and an OS command injection flaw in its configuration services. The web/API interface accepts HTTP/XML requests authenticated with a fixed vendor credential string and passes user-controlled fields into shell execution contexts without proper argument sanitization. An unauthenticated remote attacker can leverage the hard-coded credential to access endpoints such as /editBlackAndWhiteList and inject shell metacharacters inside XML parameters, resulting in arbitrary command execution as root. The same vulnerable backend is also reachable in some models through a proprietary TCP service on port 4567 that accepts a magic GUID preface and base64-encoded XML, enabling the same command injection sink. Firmware releases from mid-February 2018 and later are reported to have addressed this issue. Exploitation evidence was observed by the Shadowserver Foundation on 2025-01-28 UTC.
CVE-2025-59095 1 Dormakaba 1 Kaba Exos 9300 2026-04-15 N/A
The program libraries (DLL) and binaries used by exos 9300 contain multiple hard-coded secrets. One notable example is the function "EncryptAndDecrypt" in the library Kaba.EXOS.common.dll. This algorithm uses a simple XOR encryption technique combined with a cryptographic key (cryptoKey) to transform each character of the input string. However, it's important to note that this implementation does not provide strong encryption and should not be considered secure for sensitive data. It's more of a custom encryption approach rather than a common algorithm used in cryptographic applications. The key itself is static and based on the founder's name of the company. The functionality is for example used to encrypt the user PINs before storing them in the MSSQL database.
CVE-2023-49224 2026-04-15 8.0 High
Precor touchscreen console P62, P80, and P82 contains a default SSH public key in the authorized_keys file. A remote attacker could use this key to gain root privileges.
CVE-2025-5023 2026-04-15 7.1 High
Use of Hard-coded Credentials vulnerability in Mitsubishi Electric Corporation photovoltaic system monitor “EcoGuideTAB” PV-DR004J all versions and PV-DR004JA all versions allows an attacker within the Wi-Fi communication range between the units of the product (measurement unit and display unit) to disclose information such as generated power and electricity sold back to the grid stored in the product, tamper with or destroy stored or configured information in the product, or cause a Denial-of-Service (DoS) condition on the product, by using hardcoded user ID and password common to the product series obtained by exploiting CVE-2025-5022. The affected products discontinued in 2015, support ended in 2020.
CVE-2025-26410 2026-04-15 9.8 Critical
The firmware of all Wattsense Bridge devices contain the same hard-coded user and root credentials. The user password can be easily recovered via password cracking attempts. The recovered credentials can be used to log into the device via the login shell that is exposed by the serial interface. The backdoor user has been removed in firmware BSP >= 6.4.1.
CVE-2025-46273 2026-04-15 9.8 Critical
UNI-NMS-Lite uses hard-coded credentials that could allow an unauthenticated attacker to gain administrative privileges to all UNI-NMS managed devices.
CVE-2024-11630 1 E-lins 9 H685, H685f, H700 and 6 more 2026-04-15 7.3 High
A vulnerability has been found in E-Lins H685, H685f, H700, H720, H750, H820, H820Q, H820Q0 and H900 up to 3.2 and classified as critical. This vulnerability affects unknown code of the component OEM Backend. The manipulation leads to hard-coded credentials. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. It is recommended to change the configuration settings. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2025-64766 2 Nixos, Onlyoffice 2 Nixos, Onlyoffice 2026-04-15 5.3 Medium
NixOS's Onlyoffice is a software suite that offers online and offline tools for document editing, collaboration, and management. In versions from 22.11 to before 25.05 and versions before Unstable 25.11, a hard-coded secret was used in the NixOS module for the OnlyOffice document server to protect its file cache. An attacker with knowledge of an existing revision ID could use this secret to obtain a document. In practice, an arbitrary revision ID should be hard to obtain. The primary impact is likely the access to known documents from users with expired access. This issue was resolved in NixOS unstable version 25.11 and version 25.05.
CVE-2023-6198 2026-04-15 9.3 Critical
Use of Hard-coded Credentials vulnerability in Baicells Snap Router BaiCE_BMI on EP3011 (User Passwords modules) allows unauthorized access to the device.
CVE-2024-10025 1 Sick 52 Clv620 Firmware, Clv621 Firmware, Clv622 Firmware and 49 more 2026-04-15 9.1 Critical
A vulnerability in the .sdd file allows an attacker to read default passwords stored in plain text within the code. By exploiting these plaintext credentials, an attacker can log into affected SICK products as an “Authorized Client” if the customer has not changed the default password.
CVE-2025-55279 2026-04-15 N/A
This vulnerability exists in ZKTeco WL20 due to hard-coded private key stored in plaintext within the device firmware. An attacker with physical access could exploit this vulnerability by extracting the firmware and analyzing the binary data to retrieve private key stored in the firmware of the targeted device. Successful exploitation of this vulnerability could allow the attacker to perform unauthorized decryption of sensitive data and Man-in-the-Middle (MitM) attacks on the targeted device.
CVE-2025-33186 1 Nvidia 1 Aistore 2026-04-15 8.8 High
NVIDIA AIStore contains a vulnerability in AuthN. A successful exploit of this vulnerability might lead to escalation of privileges, information disclosure, and data tampering.
CVE-2024-28146 2026-04-15 8.4 High
The application uses several hard-coded credentials to encrypt config files during backup, to decrypt the new firmware during an update and some passwords allow a direct connection to the database server of the affected device.
CVE-2025-30122 2026-04-15 9.8 Critical
An issue was discovered on ROADCAM X3 devices. It has a uniform default credential set that cannot be modified by users, making it easy for attackers to gain unauthorized access to multiple devices.
CVE-2025-30123 2026-04-15 9.8 Critical
An issue was discovered on ROADCAM X3 devices. The mobile app APK (Viidure) contains hardcoded FTP credentials for the FTPX user account, enabling attackers to gain unauthorized access and extract sensitive recorded footage from the device.
CVE-2024-28747 1 Ifm 2 Smart Plc Ac14xx Firmware, Smart Plc Ac4xxs Firmware 2026-04-15 9.8 Critical
An unauthenticated remote attacker can use the hard-coded credentials to access the SmartSPS devices with high privileges.
CVE-2024-57811 2026-04-15 9.1 Critical
In Eaton X303 3.5.16 - X303 3.5.17 Build 712, an attacker with network access to a XC-303 PLC can login as root over SSH. The root password is hardcoded in the firmware. NOTE: This vulnerability appears in versions that are no longer supported by Eaton.