| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Polkadot Frontier is an Ethereum and EVM compatibility layer for Polkadot and Substrate. In versions prior to commit 36f70d1, the Curve25519Add and Curve25519ScalarMul precompiles incorrectly handle invalid Ristretto point representations. Instead of returning an error, they silently treat invalid input bytes as the Ristretto identity element, leading to potentially incorrect cryptographic results. This is fixed in commit 36f70d1. |
| Padding oracle attack vulnerability in Oberon microsystem AG’s ocrypto library in all versions since 3.1.0 and prior to 3.9.2 allows an attacker to recover plaintexts via timing measurements of AES-CBC PKCS#7 decrypt operations. |
| CyberGhostVPNSetup.exe (Windows installer) is signed using the weak cryptographic hash algorithm SHA-1, which is vulnerable to collision attacks. This allows a malicious actor to craft a fake installer with a forged SHA-1 certificate that may still be accepted by Windows signature verification mechanisms, particularly on systems without strict SmartScreen or trust policy enforcement. Additionally, the installer lacks High Entropy Address Space Layout Randomization (ASLR), as confirmed by BinSkim (BA2015 rule) and repeated WinDbg analysis. The binary consistently loads into predictable memory ranges, increasing the success rate of memory corruption exploits. These two misconfigurations, when combined, significantly lower the bar for successful supply-chain style attacks or privilege escalation through fake installers. |
| HiveOS through 0.6-102@191212 ships with SSH host keys baked into the installation image, which allows man-in-the-middle attacks and makes identification of all public IPv4 nodes trivial with Shodan.io. NOTE: as of 2019-09-26, the vendor indicated that they would consider fixing this. |
| Use of hard-coded cryptographic key issue exists in "Kura Sushi Official App Produced by EPARK" for Android versions prior to 3.8.5. If this vulnerability is exploited, a local attacker may obtain the login ID and password for the affected product. |
| Use of Hard-coded Cryptographic Key vulnerability in ABB RMC-100, ABB RMC-100 LITE.
When the REST interface is enabled by the user, and an attacker gains access to
source code and control network, the attacker can bypass the REST interface authentication and gain access to MQTT configuration data.
This issue affects RMC-100: from 2105457-043 through 2105457-045; RMC-100 LITE: from 2106229-015 through 2106229-016. |
| Use of hard-coded cryptographic key issue exists in BizRobo! all versions. Credentials inside robot files may be obtained if the encryption key is available.
The vendor provides the workaround information and recommends to apply it to the deployment environment. |
| Missing cryptographic key commitment in the AWS SDK for Ruby may allow a user with write access to the S3 bucket to introduce a new EDK that decrypts to different plaintext when the encrypted data key is stored in an "instruction file" instead of S3's metadata record.
To mitigate this issue, upgrade AWS SDK for Ruby to version 1.208.0 or later. |
| A vulnerability has been identified in APOGEE PXC Series (BACnet) (All versions), APOGEE PXC Series (P2 Ethernet) (All versions), TALON TC Series (BACnet) (All versions). Affected devices contain a weak encryption mechanism based on a hard-coded key.
This could allow an attacker to guess or decrypt the password from the cyphertext. |
| Smadar SPS – CWE-327: Use of a Broken or Risky Cryptographic Algorithm |
| Missing cryptographic key commitment in the Amazon S3 Encryption Client for Go may allow a user with write access to the S3 bucket to introduce a new EDK that decrypts to different plaintext when the encrypted data key is stored in an "instruction file" instead of S3's metadata record.
To mitigate this issue, upgrade Amazon S3 Encryption Client for Go to version 4.0 or later. |
| A vulnerability has been identified in RUGGEDCOM i800 (All versions), RUGGEDCOM i801 (All versions), RUGGEDCOM i802 (All versions), RUGGEDCOM i803 (All versions), RUGGEDCOM M2100 (All versions), RUGGEDCOM M2200 (All versions), RUGGEDCOM M969 (All versions), RUGGEDCOM RMC30 (All versions), RUGGEDCOM RMC8388 V4.X (All versions), RUGGEDCOM RMC8388 V5.X (All versions < V5.10.0), RUGGEDCOM RP110 (All versions), RUGGEDCOM RS1600 (All versions), RUGGEDCOM RS1600F (All versions), RUGGEDCOM RS1600T (All versions), RUGGEDCOM RS400 (All versions), RUGGEDCOM RS401 (All versions), RUGGEDCOM RS416 (All versions), RUGGEDCOM RS416P (All versions), RUGGEDCOM RS416Pv2 V4.X (All versions), RUGGEDCOM RS416Pv2 V5.X (All versions < V5.10.0), RUGGEDCOM RS416v2 V4.X (All versions), RUGGEDCOM RS416v2 V5.X (All versions < V5.10.0), RUGGEDCOM RS8000 (All versions), RUGGEDCOM RS8000A (All versions), RUGGEDCOM RS8000H (All versions), RUGGEDCOM RS8000T (All versions), RUGGEDCOM RS900 (All versions), RUGGEDCOM RS900 (32M) V4.X (All versions), RUGGEDCOM RS900 (32M) V5.X (All versions < V5.10.0), RUGGEDCOM RS900G (All versions), RUGGEDCOM RS900G (32M) V4.X (All versions), RUGGEDCOM RS900G (32M) V5.X (All versions < V5.10.0), RUGGEDCOM RS900GP (All versions), RUGGEDCOM RS900L (All versions), RUGGEDCOM RS900M-GETS-C01 (All versions), RUGGEDCOM RS900M-GETS-XX (All versions), RUGGEDCOM RS900M-STND-C01 (All versions), RUGGEDCOM RS900M-STND-XX (All versions), RUGGEDCOM RS900W (All versions), RUGGEDCOM RS910 (All versions), RUGGEDCOM RS910L (All versions), RUGGEDCOM RS910W (All versions), RUGGEDCOM RS920L (All versions), RUGGEDCOM RS920W (All versions), RUGGEDCOM RS930L (All versions), RUGGEDCOM RS930W (All versions), RUGGEDCOM RS940G (All versions), RUGGEDCOM RS969 (All versions), RUGGEDCOM RSG2100 (All versions), RUGGEDCOM RSG2100 (32M) V4.X (All versions), RUGGEDCOM RSG2100 (32M) V5.X (All versions < V5.10.0), RUGGEDCOM RSG2100P (All versions), RUGGEDCOM RSG2100P (32M) V4.X (All versions), RUGGEDCOM RSG2100P (32M) V5.X (All versions < V5.10.0), RUGGEDCOM RSG2200 (All versions), RUGGEDCOM RSG2288 V4.X (All versions), RUGGEDCOM RSG2288 V5.X (All versions < V5.10.0), RUGGEDCOM RSG2300 V4.X (All versions), RUGGEDCOM RSG2300 V5.X (All versions < V5.10.0), RUGGEDCOM RSG2300P V4.X (All versions), RUGGEDCOM RSG2300P V5.X (All versions < V5.10.0), RUGGEDCOM RSG2488 V4.X (All versions), RUGGEDCOM RSG2488 V5.X (All versions < V5.10.0), RUGGEDCOM RSG907R (All versions < V5.10.0), RUGGEDCOM RSG908C (All versions < V5.10.0), RUGGEDCOM RSG909R (All versions < V5.10.0), RUGGEDCOM RSG910C (All versions < V5.10.0), RUGGEDCOM RSG920P V4.X (All versions), RUGGEDCOM RSG920P V5.X (All versions < V5.10.0), RUGGEDCOM RSL910 (All versions < V5.10.0), RUGGEDCOM RST2228 (All versions < V5.10.0), RUGGEDCOM RST2228P (All versions < V5.10.0), RUGGEDCOM RST916C (All versions < V5.10.0), RUGGEDCOM RST916P (All versions < V5.10.0). The affected devices support the TLS_ECDHE_ECDSA_WITH_AES_128_CBC_SHA256 cipher suite, which uses CBC (Cipher Block Chaining) mode that is known to be vulnerable to timing attacks. This could allow an attacker to compromise the integrity and confidentiality of encrypted communications. |
| This vulnerability exists in Tapo C500 Wi-Fi camera due to hard-coded RSA private key embedded within the device firmware. An attacker with physical access could exploit this vulnerability to obtain cryptographic private keys which can then be used to perform impersonation, data decryption and man in the middle attacks on the targeted device. |
| ESPTouch is a connection protocol for internet of things devices. In the ESPTouchV2 protocol, while there is an option to use a custom AES key, there is no option to set the IV (Initialization Vector) prior to versions 5.3.2, 5.2.4, 5.1.6, and 5.0.8. The IV is set to zero and remains constant throughout the product's lifetime. In AES/CBC mode, if the IV is not properly initialized, the encrypted output becomes deterministic, leading to potential data leakage. To address the aforementioned issues, the application generates a random IV when activating the AES key starting in versions 5.3.2, 5.2.4, 5.1.6, and 5.0.8. This IV is then transmitted along with the provision data to the provision device. The provision device has also been equipped with a parser for the AES IV. The upgrade is applicable for all applications and users of ESPTouch v2 component from ESP-IDF. As it is implemented in the ESP Wi-Fi stack, there is no workaround for the user to fix the application layer without upgrading the underlying firmware. |
| A static initialization vector (IV) in the encrypt function of netbird management's service from v0.23.2 to v0.29.1 allows attackers to obtain sensitive information (email addresses) when in possession of the audit events database. |
| A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V9.64), SIPROTEC 5 6MD85 (CP200) (All versions), SIPROTEC 5 6MD85 (CP300) (All versions < V9.64), SIPROTEC 5 6MD86 (CP200) (All versions), SIPROTEC 5 6MD86 (CP300) (All versions < V9.64), SIPROTEC 5 6MD89 (CP300) (All versions < V9.64), SIPROTEC 5 6MU85 (CP300) (All versions < V9.64), SIPROTEC 5 7KE85 (CP200) (All versions), SIPROTEC 5 7KE85 (CP300) (All versions < V9.64), SIPROTEC 5 7SA82 (CP100) (All versions < V8.90), SIPROTEC 5 7SA82 (CP150) (All versions < V9.65), SIPROTEC 5 7SA84 (CP200) (All versions), SIPROTEC 5 7SA86 (CP200) (All versions), SIPROTEC 5 7SA86 (CP300) (All versions < V9.65), SIPROTEC 5 7SA87 (CP200) (All versions), SIPROTEC 5 7SA87 (CP300) (All versions < V9.65), SIPROTEC 5 7SD82 (CP100) (All versions < V8.90), SIPROTEC 5 7SD82 (CP150) (All versions < V9.65), SIPROTEC 5 7SD84 (CP200) (All versions), SIPROTEC 5 7SD86 (CP200) (All versions), SIPROTEC 5 7SD86 (CP300) (All versions < V9.65), SIPROTEC 5 7SD87 (CP200) (All versions), SIPROTEC 5 7SD87 (CP300) (All versions < V9.65), SIPROTEC 5 7SJ81 (CP100) (All versions < V8.89), SIPROTEC 5 7SJ81 (CP150) (All versions < V9.65), SIPROTEC 5 7SJ82 (CP100) (All versions < V8.89), SIPROTEC 5 7SJ82 (CP150) (All versions < V9.65), SIPROTEC 5 7SJ85 (CP200) (All versions), SIPROTEC 5 7SJ85 (CP300) (All versions < V9.65), SIPROTEC 5 7SJ86 (CP200) (All versions), SIPROTEC 5 7SJ86 (CP300) (All versions < V9.65), SIPROTEC 5 7SK82 (CP100) (All versions < V8.89), SIPROTEC 5 7SK82 (CP150) (All versions < V9.65), SIPROTEC 5 7SK85 (CP200) (All versions), SIPROTEC 5 7SK85 (CP300) (All versions < V9.65), SIPROTEC 5 7SL82 (CP100) (All versions < V8.90), SIPROTEC 5 7SL82 (CP150) (All versions < V9.65), SIPROTEC 5 7SL86 (CP200) (All versions), SIPROTEC 5 7SL86 (CP300) (All versions < V9.65), SIPROTEC 5 7SL87 (CP200) (All versions), SIPROTEC 5 7SL87 (CP300) (All versions < V9.65), SIPROTEC 5 7SS85 (CP200) (All versions), SIPROTEC 5 7SS85 (CP300) (All versions < V9.64), SIPROTEC 5 7ST85 (CP200) (All versions), SIPROTEC 5 7ST85 (CP300) (All versions < V9.64), SIPROTEC 5 7ST86 (CP300) (All versions < V9.64), SIPROTEC 5 7SX82 (CP150) (All versions < V9.65), SIPROTEC 5 7SX85 (CP300) (All versions < V9.65), SIPROTEC 5 7UM85 (CP300) (All versions < V9.64), SIPROTEC 5 7UT82 (CP100) (All versions < V8.90), SIPROTEC 5 7UT82 (CP150) (All versions < V9.65), SIPROTEC 5 7UT85 (CP200) (All versions), SIPROTEC 5 7UT85 (CP300) (All versions < V9.65), SIPROTEC 5 7UT86 (CP200) (All versions), SIPROTEC 5 7UT86 (CP300) (All versions < V9.65), SIPROTEC 5 7UT87 (CP200) (All versions), SIPROTEC 5 7UT87 (CP300) (All versions < V9.65), SIPROTEC 5 7VE85 (CP300) (All versions < V9.64), SIPROTEC 5 7VK87 (CP200) (All versions), SIPROTEC 5 7VK87 (CP300) (All versions < V9.65), SIPROTEC 5 7VU85 (CP300) (All versions < V9.64), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.1) (All versions < V9.62 installed on CP150 and CP300 devices), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.1) (All versions installed on CP200 devices), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.1) (All versions < V8.89 installed on CP100 devices), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 1) (All versions installed on CP200 devices), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 1) (All versions < V9.62 installed on CP150 and CP300 devices), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 1) (All versions < V8.89 installed on CP100 devices), SIPROTEC 5 Communication Module ETH-BD-2FO (All versions < V9.62), SIPROTEC 5 Compact 7SX800 (CP050) (All versions < V9.64). The affected devices are supporting weak ciphers on several ports (443/tcp for web, 4443/tcp for DIGSI 5 and configurable port for syslog over TLS).
This could allow an unauthorized attacker in a man-in-the-middle position to decrypt any data passed over to and from those ports. |
| The certificate and private key used for providing transport layer security for connections to the web interface (TCP port 443) is hard-coded in the firmware and are shipped with the update files. An attacker can use the private key to perform man-in-the-middle attacks against users of the admin interface. The files are located in /etc/ssl (e.g. salia.local.crt, salia.local.key and salia.local.pem). There is no option to upload/configure custom TLS certificates. |
| The NXP Data Co-Processor (DCP) is a built-in hardware module for specific NXP SoCs¹ that implements a dedicated AES cryptographic engine for encryption/decryption operations. The dcp_tool reference implementation included in the repository selected the test key, regardless of its `-t` argument. This issue has been patched in commit 26a7. |
| In illumos illumos-gate 2024-02-15, an error occurs in the elliptic curve point addition algorithm that uses mixed Jacobian-affine coordinates, causing the algorithm to yield a result of POINT_AT_INFINITY when it should not. A man-in-the-middle attacker could use this to interfere with a connection, resulting in an attacked party computing an incorrect shared secret. |
| RLPx 5 has two CTR streams based on the same key, IV, and nonce. This can facilitate decryption on a private network. |