| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| The authenticated time setting capability of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS command are improperly neutralized when certain fields are passed to the underlying OS. |
| A vulnerability, which was classified as problematic, was found in Done-0 Jank up to 322caebbad10568460364b9667aa62c3080bfc17. Affected is an unknown function of the file internal/utils/jwt_utils.go of the component JWT Token Handler. The manipulation of the argument accessSecret/refreshSecret with the input jank-blog-secret/jank-blog-refresh-secret leads to use of hard-coded password. It is possible to launch the attack remotely. The complexity of an attack is rather high. The exploitability is told to be difficult. The exploit has been disclosed to the public and may be used. Continious delivery with rolling releases is used by this product. Therefore, no version details of affected nor updated releases are available. |
| FydeOS for PC 17.1 R114, FydeOS for VMware 17.0 R114, FydeOS for You 17.1 R114, and OpenFyde R114 were discovered to be configured with the root password saved as a wildcard. This allows attackers to gain root access without a password. |
| An Execution with Unnecessary Privileges vulnerability has been identified in Moxa’s network security appliances and routers. A flaw in broken access control has been identified in the /api/v1/setting/data endpoint of the affected device. This flaw allows a low-privileged authenticated user to call the API without the required permissions, thereby gaining the ability to access or modify system configuration data. Successful exploitation may lead to privilege escalation, allowing the attacker to access or modify sensitive system settings. While the overall impact is high, there is no loss of confidentiality or integrity within any subsequent systems. |
| Toshiba printers contain hardcoded credentials. As for the affected products/models/versions, see the reference URL. |
| A vulnerability has been found in Zytec Dalian Zhuoyun Technology Central Authentication Service 3. Affected by this vulnerability is an unknown functionality of the file /index.php/auth/Ops/git of the component HTTP Header Handler. The manipulation of the argument Authorization leads to use of hard-coded password. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| A hard-coded weak password vulnerability has been discovered in all Magic-branded devices from Chinese network equipment manufacturer H3C. The vulnerability stems from the use of a hard-coded weak password for the root account in the /etc/shadow configuration or even the absence of any password at all. Some of these devices have the Telnet service enabled by default, or users can choose to enable the Telnet service in other device management interfaces (e.g. /debug.asp or /debug_telnet.asp). In addition, these devices have related interfaces called Virtual Servers, which can map the devices to the public network, posing the risk of remote attacks. Therefore, attackers can obtain the highest root privileges of the devices through the Telnet service using the weak password hardcoded in the firmware (or without a password), and remote attacks are possible. |
| Minecraft RCON Terminal is a VS Code extension that streamlines Minecraft server management. Versions 0.1.0 through 2.0.6 stores passwords using VS Code's configuration API which writes to settings.json in plaintext. This issue is fixed in version 2.1.0. |
| HCL Workload Scheduler stores user credentials in plain text which can be read by a local user. |
| A vulnerability was determined in TaleLin Lin-CMS up to 0.6.0. This affects an unknown part of the file /tests/config.py of the component Tests Folder. This manipulation of the argument username/password causes password in configuration file. The attack is possible to be carried out remotely. The complexity of an attack is rather high. It is indicated that the exploitability is difficult. The exploit has been publicly disclosed and may be utilized. |
| A flaw was found in how Quay's database is stored in plain-text in mirror-registry on the jinja's config.yaml file. This flaw allows a malicious actor with access to this file to gain access to Quay's database. |
| A vulnerability exists in the SOAP Web services of the Asset
Suite versions listed below. If successfully exploited, an attacker
could gain unauthorized access to the product and the time window of a possible password attack could be expanded. |
| The access control in CemiPark software stores integration (e.g. FTP or SIP) credentials in plain-text. An attacker who gained unauthorized access to the device can retrieve clear text passwords used by the system.This issue affects CemiPark software: 4.5, 4.7, 5.03 and potentially others. The vendor refused to provide the specific range of affected products.
|
| A vulnerability exists in multiple Radiometer products that allow an attacker with physical access to the analyzer possibility to extract credential information. The vulnerability is due to a weakness in the design and insufficient credential protection in operating system.
Other related CVE's are CVE-2025-14095 & CVE-2025-14097.
Affected customers have been informed about this vulnerability. This CVE is being published to provide transparency.
Required Configuration for Exposure:
Attacker requires physical access to the analyzer.
Temporary work Around:
Only authorized people can physically access the analyzer.
Permanent solution:
Local Radiometer representatives will contact all affected customers to discuss a permanent solution.
Exploit Status:
Researchers have provided a working proof-of-concept (PoC). Radiometer is not aware of any public exploit code at the time of this publication. |
| The scanner device boots into a kiosk mode by default and opens the Scan2Net interface in a browser window. This browser is run with the permissions of the root user. There are also several other applications running as root user. This can be confirmed by running "ps aux" as the root user and observing the output. |
| An issue was discovered in Grandstream GXP14XX 1.0.8.9 and GXP16XX 1.0.7.13, allows remote attackers to escalate privileges via incorrect access control using an end-user session-identity token. |
|
In AutomationDirect C-MORE EA9 HMI,
credentials used by the platform are stored as plain text on the device.
|
| SMM callout vulnerability within the AmdPlatformRasSspSmm driver could allow a ring 0 attacker to modify boot services handlers, potentially resulting in arbitrary code execution. |
| Asseco InfoMedica is a comprehensive solution used to manage both administrative and medical tasks in the healthcare sector. Passwords of all users are stored in a database in an encoded format. An attacker in possession of these encoded passwords is able to decode them by using an algorithm embedded in the client-side part of the software.
This vulnerability has been fixed in versions 4.50.1 and 5.38.0 |
| Vulnerability in Spotfire Spotfire Analyst, Spotfire Spotfire Server, Spotfire Spotfire for AWS Marketplace allows In the case of the installed Windows client: Successful execution of this vulnerability will result in an attacker being able to run arbitrary code.This requires human interaction from a person other than the attacker., In the case of the Web player (Business Author): Successful execution of this vulnerability via the Web Player, will result in the attacker being able to run arbitrary code as the account running the Web player process, In the case of Automation Services: Successful execution of this vulnerability will result in an attacker being able to run arbitrary code via Automation Services..This issue affects Spotfire Analyst: from 12.0.9 through 12.5.0, from 14.0 through 14.0.2; Spotfire Server: from 12.0.10 through 12.5.0, from 14.0 through 14.0.3, from 14.2.0 through 14.3.0; Spotfire for AWS Marketplace: from 14.0 before 14.3.0. |