| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Huawei smart phones with software earlier than Vicky-AL00AC00B172D versions have a Factory Reset Protection (FRP) bypass security vulnerability. When re-configuring the mobile phone using the factory reset protection (FRP) function, an attacker can login the Talkback mode and can perform some operations to bypass the Google account verification. As a result, the FRP function is bypassed. |
| Mahara 1.8 before 1.8.6 and 1.9 before 1.9.4 and 1.10 before 1.10.1 and 15.04 before 15.04.0 are vulnerable to old sessions not being invalidated after a password change. |
| In Kanboard before 1.0.47, by altering form data, an authenticated user can edit columns of a private project of another user. |
| Open redirect vulnerability in the lmadmin component in Flexera FlexNet Publisher (aka Flex License Manager) 11.14.1 and earlier, as used in Citrix License Server for Windows and the Citrix License Server VPX, allows remote attackers to redirect users to arbitrary web sites and conduct phishing attacks via unspecified vectors. |
| There is a reachable assertion in the Internal::TiffReader::visitDirectory function in tiffvisitor.cpp of Exiv2 0.26 that will lead to a remote denial of service attack via crafted input. |
| kernel/bpf/verifier.c in the Linux kernel through 4.14.8 allows local users to cause a denial of service (memory corruption) or possibly have unspecified other impact by leveraging mishandling of 32-bit ALU ops. |
| ME906s-158 earlier than ME906S_Installer_13.1805.10.3 versions has a privilege elevation vulnerability. An attacker could exploit this vulnerability to modify the configuration information containing malicious files and trick users into executing the files, resulting in the execution of arbitrary code. |
| There is a reachable assertion abort in the function jpc_floorlog2() in jpc/jpc_math.c in JasPer 2.0.12 that will lead to a remote denial of service attack. |
| A vulnerability has been identified in SIMATIC Drive Controller family (All versions >= V2.9.2 < V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions >= V21.9 < V21.9.4), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions >= V4.5.0 < V4.5.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.9.2 < V2.9.4), SIMATIC S7-1500 Software Controller (All versions >= V21.9 < V21.9.4), SIMATIC S7-PLCSIM Advanced (All versions >= V4.0 < V4.0 SP1), SIPLUS TIM 1531 IRC (All versions < V2.3.6), TIM 1531 IRC (All versions < V2.3.6). An unauthenticated attacker could cause a denial-of-service condition in a PLC when sending specially prepared packets over port 102/tcp. A restart of the affected device is needed to restore normal operations. |
| A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V2.9.2), SIMATIC Drive Controller family (All versions >= V2.9.2 < V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V21.9), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions >= V21.9 < V21.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 Ready4Linux (All versions), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.5.0), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions >= V4.5.0 < V4.5.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.9.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.9.2 < V2.9.4), SIMATIC S7-1500 Software Controller (All versions < V21.9), SIMATIC S7-1500 Software Controller (All versions >= V21.9 < V21.9.4), SIMATIC S7-PLCSIM Advanced (All versions < V4.0), SIMATIC S7-PLCSIM Advanced (All versions >= V4.0 < V4.0 SP1), SIPLUS TIM 1531 IRC (All versions < V2.3.6), TIM 1531 IRC (All versions < V2.3.6). An unauthenticated attacker could cause a denial-of-service condition in a PLC when sending specially prepared packet over port 102/tcp. A restart of the affected device is needed to restore normal operations. |
| An “uninitialized variable” code execution vulnerability exists in the
Rockwell Automation Arena®
that could allow a threat actor to craft a DOE file and force the software to access a variable before it being initialized. If exploited, a threat actor could leverage this vulnerability to execute arbitrary code. To exploit this vulnerability, a legitimate user must execute the malicious code crafted by the threat actor. |
| In HCL Digital Experience, URLs can be constructed to redirect users to untrusted sites.
|
| In Multiple Locations, there is a possibility to launch arbitrary protected activities due to a confused deputy. This could lead to local escalation of privilege with User execution privileges needed. User interaction is not needed for exploitation.Product: AndroidVersions: Android-13Android ID: A-242845514 |
| In onPreferenceClick of AccountTypePreferenceLoader.java, there is a possible way to retrieve protected files from the Settings app due to a confused deputy. This could lead to local information disclosure with no additional execution privileges needed. User interaction is not needed for exploitation.Product: AndroidVersions: Android-13Android ID: A-220733496 |
| In SAP Solution Manager (Enterprise Search) - versions 740, and 750, an unauthenticated attacker can generate a link that, if clicked by a logged-in user, can be redirected to a malicious page that could read or modify sensitive information, or expose the user to a phishing attack, with little impact on confidentiality and integrity.
|
| HDF5 Library through 1.14.3 allows stack consumption in the function H5E_printf_stack in H5Eint.c. |
| mod_auth_openidc is an OpenID Certified™ authentication and authorization module for the Apache 2.x HTTP server. Versions prior to 2.4.12.2 are vulnerable to Open Redirect. When providing a logout parameter to the redirect URI, the existing code in oidc_validate_redirect_url() does not properly check for URLs that start with /\t, leading to an open redirect. This issue has been patched in version 2.4.12.2. Users unable to upgrade can mitigate the issue by configuring mod_auth_openidc to only allow redirection when the destination matches a given regular expression with OIDCRedirectURLsAllowed. |
| An authenticated user can perform XML eXternal Entity injection in Management Console in Symantec Identity Manager 14.4 |
| Improper initialization of x87 and SSE floating-point configuration registers in the __scone_entry component of SCONE before 5.8.0 for Intel SGX allows a local attacker to compromise the execution integrity of floating-point operations in an enclave or access sensitive information via side-channel analysis. |
| An issue was discovered in the libsofia-sip fork in drachtio-server before 0.8.20. It allows remote attackers to cause a denial of service (daemon crash) via a crafted UDP message that leads to a failure of the libsofia-sip-ua/tport/tport.c self assertion. |