| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Electron is a framework for writing cross-platform desktop applications using JavaScript, HTML and CSS. Prior to 39.8.5, 40.8.5, 41.1.0, and 42.0.0-alpha.5, apps that call clipboard.readImage() may be vulnerable to a denial of service. If the system clipboard contains image data that fails to decode, the resulting null bitmap is passed unchecked to image construction, triggering a controlled abort and crashing the process. Apps are only affected if they call clipboard.readImage(). Apps that do not read images from the clipboard are not affected. This issue does not allow memory corruption or code execution. This vulnerability is fixed in 39.8.5, 40.8.5, 41.1.0, and 42.0.0-alpha.5. |
| Improper validation of specified type of input in M365 Copilot allows an unauthorized attacker to disclose information over a network. |
| systemd, a system and service manager, (as PID 1) hits an assert and freezes execution when an unprivileged IPC API call is made with spurious data. On version v249 and older the effect is not an assert, but stack overwriting, with the attacker controlled content. From version v250 and newer this is not possible as the safety check causes an assert instead. This IPC call was added in v239, so versions older than that are not affected. Versions 260-rc1, 259.2, 258.5, and 257.11 contain patches. No known workarounds are available. |
| The SAP Approuter Node.js package version v16.7.1 and before is vulnerable to Authentication bypass. When trading an authorization code an attacker can steal the session of the victim by injecting malicious payload causing High impact on confidentiality and integrity of the application |
| Due to missing input validation, an attacker with high privilege access to ABAP reports could delete the content of arbitrary database tables, if the tables are not protected by an authorization group. This leads to a high impact on integrity and availability of the database but no impact on confidentiality. |
| The VAPIX API port.cgi did not have sufficient input validation, which may result in process crashes and impact usability. This vulnerability can only be exploited after authenticating with a viewer- operator- or administrator-privileged service account. |
| Net::CIDR::Set versions 0.10 through 0.13 for Perl does not properly handle leading zero characters in IP CIDR address strings, which could allow attackers to bypass access control that is based on IP addresses.
Leading zeros are used to indicate octal numbers, which can confuse users who are intentionally using octal notation, as well as users who believe they are using decimal notation.
Net::CIDR::Set used code from Net::CIDR::Lite, which had a similar vulnerability CVE-2021-47154. |
| Nokia Single RAN baseband software versions earlier than 24R1-SR 2.1 MP contain a SOAP message input validation flaw, which in theory could potentially be used for causing resource exhaustion in the Single RAN baseband OAM service.
No practical exploit has been detected for this flaw. However, the issue has been corrected starting from release 24R1-SR 2.1 MP by adding sufficient input validation for received SOAP requests, effectively mitigating the reported issue. |
| An unauthenticated remote attacker can exploit input validation in cmd services of the devices, allowing them to disrupt system operations and potentially cause a denial-of-service. |
| A Guard Tour VAPIX API parameter allowed the use of arbitrary values and can be incorrectly called, allowing an attacker to block access to the guard tour configuration page in the web interface of the Axis device. |
| An unauthorised attacker within bluetooth range may use an improper validation during the BLE connection request to deadlock the affected devices. |
| In Perfex Crm < 3.2.1, an authenticated attacker can send a crafted HTTP POST request to the affected upload_sales_file endpoint. By providing malicious input in the rel_id parameter, combined with improper input validation, the attacker can bypass restrictions and upload arbitrary files to directories of their choice, potentially leading to remote code execution or server compromise. |
| In KDE Connect before 1.33.0 on Android, malicious device IDs (sent via broadcast UDP) could cause an application crash. |
| The urllib.parse.urlsplit() and urlparse() functions improperly validated bracketed hosts (`[]`), allowing hosts that weren't IPv6 or IPvFuture. This behavior was not conformant to RFC 3986 and potentially enabled SSRF if a URL is processed by more than one URL parser. |
| An unauthenticated remote attacker can send a specially crafted Modbus read command to the device which leads to a denial of service. |
| Improper Validation of Specified Type of Input vulnerability in OpenText™ Content Management (Extended ECM) allows Parameter Injection.
A bad actor with the required OpenText Content Management privileges (not root) could expose
the vulnerability to carry out a remote code execution attack on the target system.
This issue affects Content Management (Extended ECM): from 10.0 through 24.4
with WebReports module
installed and enabled. |
| An improper parsing vulnerability was reported in the FileZ client that could allow a crafted file in the FileZ directory to read arbitrary files on the device due to URL preloading. |
| This vulnerability could lead to denial-of-service or service crashes. Exploitation of the moxa_cmd service, because of insufficient input validation, allows attackers to disrupt operations. If exposed to public networks, the vulnerability poses a significant remote threat, potentially allowing attackers to shut down affected systems. |
| A security issue exists due to improper handling of CIP Class 32’s request when a module is inhibited on the 5094-IF8 device. It causes the module to enter a fault state with the Module LED flashing red. Upon un-inhibiting, the module returns a connection fault (Code 16#0010), and the module cannot recover without a power cycle. |
| A security issue exists due to improper handling of CIP Class 32’s request when a module is inhibited on the 5094-IY8 device. It causes the module to enter a fault state with the Module LED flashing red. Upon un-inhibiting, the module returns a connection fault (Code 16#0010), and the module cannot recover without a power cycle. |