Export limit exceeded: 24528 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (24528 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2025-23299 | 1 Nvidia | 2 Bluefield, Connectx | 2026-04-15 | 6.7 Medium |
| NVIDIA Bluefield and ConnectX contain a vulnerability in the management interface that could allow a malicious actor with high privilege access to execute arbitrary code. | ||||
| CVE-2024-1628 | 2026-04-15 | 8.4 High | ||
| OS command injection vulnerabilities in GE HealthCare ultrasound devices | ||||
| CVE-2025-3873 | 2026-04-15 | N/A | ||
| The following APIs for the Silcon Labs SiWx91x prior to vesion 3.4.0 failed to check the size of the output buffer of the caller which could lead to data corruption on the host (Cortex-M4) application. sl_si91x_aes sl_si91x_gcm sl_si91x_ccm sl_si91x_sha | ||||
| CVE-2025-33234 | 1 Nvidia | 1 Runx | 2026-04-15 | 7.8 High |
| NVIDIA runx contains a vulnerability where an attacker could cause a code injection. A successful exploit of this vulnerability might lead to code execution, denial of service, escalation of privileges, information disclosure, and data tampering. | ||||
| CVE-2025-34082 | 1 Igel | 1 Igel Os | 2026-04-15 | N/A |
| A command injection vulnerability exists in IGEL OS versions prior to 11.04.270 within the Secure Terminal and Secure Shadow services. The flaw arises due to improper input sanitization in the handling of specially crafted PROXYCMD commands on TCP ports 30022 and 5900. An unauthenticated attacker with network access to a vulnerable device can inject arbitrary commands, leading to remote code execution with elevated privileges. NOTE: IGEL OS v10.x has reached end-of-life (EOL) status. | ||||
| CVE-2024-5672 | 2026-04-15 | 7.2 High | ||
| A high privileged remote attacker can execute arbitrary system commands via GET requests due to improper neutralization of special elements used in an OS command. | ||||
| CVE-2024-42029 | 1 Xdg | 1 Desktop Portal Hyperland | 2026-04-15 | 6.3 Medium |
| xdg-desktop-portal-hyprland (aka an XDG Desktop Portal backend for Hyprland) before 1.3.3 allows OS command execution, e.g., because single quotes are not used when sending a list of app IDs and titles via the environment. | ||||
| CVE-2025-26055 | 2026-04-15 | 6.5 Medium | ||
| An OS Command Injection vulnerability exists in the Infinxt iEdge 100 2.1.32 Troubleshoot module, specifically in the tracertVal parameter of the Tracert function. | ||||
| CVE-2025-11964 | 2 Microsoft, Tcpdump | 2 Windows, Libpcap | 2026-04-15 | 1.9 Low |
| On Windows only, if libpcap needs to convert a Windows error message to UTF-8 and the message includes characters that UTF-8 represents using 4 bytes, utf_16le_to_utf_8_truncated() can write data beyond the end of the provided buffer. | ||||
| CVE-2025-6225 | 2026-04-15 | N/A | ||
| Kieback&Peter Neutrino-GLT product is used for building management. It's web component "SM70 PHWEB" is vulnerable to shell command injection via login form. The injected commands would execute with low privileges. The vulnerability has been fixed in version 9.40.02 | ||||
| CVE-2024-43649 | 2026-04-15 | 8.8 High | ||
| Authenticated command injection in the filename of a <redacted>.exe request leads to remote code execution as the root user. This issue affects Iocharger firmware for AC models before version 24120701. Likelihood: Moderate – This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all <redacted> fields. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a payload. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: This attack can be performed over any network conenction serving the web interfacr (AV:N), and there are not additional mitigating measures that need to be circumvented (AC:L) or other prerequisites (AT:N). The attack does require privileges, but the level does not matter (PR:L), there is no user interaction required (UI:N). The attack leeds to a full compromised of the charger (VC:H/VI:H/VA:H) and a compromised charger can be used to "pivot" to networks that should normally not be reachable (SC:L/SI:L/SA:H). Because this is an EV chargers with significant pwoer, there is a potential safety imp0act (S:P). THis attack can be automated (AU:Y). | ||||
| CVE-2024-43650 | 2026-04-15 | N/A | ||
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root This issue affects firmware versions before 24120701. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: The attack can be executed over any network connection serving the web interface (AV:N). There are no additional measures that need to be circumvented (AC:L) or attack preconditions (AT:N). THe attack is privileged, but the level does not matter (PR:L) and does not require user interaction (UI:N). Attack leads to full system compromised (VC:H/VI:H/VA:H) and compromised devices can be used to "pivot" to other networks that should be unreachable (SC:L/SI:L/SA:H). Because this an EV charger using high power, there is a potential safety impact (S:P). The attack can be automated (AU:Y). | ||||
| CVE-2024-43651 | 2026-04-15 | N/A | ||
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC models before version 241207101 Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network connection serving the web interface is vulnerable (AV:N) and there are no additional measures to circumvent (AC:L) nor does the attack require special conditions to be present (AT:N). The attack requires authentication, but the level does not matter (PR:L), nor is user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H) and a compromised device can be used to potentially "pivot" into a network that should nopt be reachable (SC:L/SI:L/SA:H). Because this is an EV charger handing significant power, there is a potential safety impact (S:P). THe attack can be autometed (AU:Y). | ||||
| CVE-2024-43654 | 2026-04-15 | 8.8 High | ||
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root This issue affects all Iocharger AC EV charger models on a firmware version before 25010801. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y). | ||||
| CVE-2024-43657 | 2026-04-15 | 8.8 High | ||
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: High. However, the attacker will need a (low privilege) account to gain access to the action.exe CGI binary and upload the crafted firmware file, or convince a user with such access to upload it. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y). | ||||
| CVE-2025-41684 | 1 Weidmueller | 3 Ie-sr-2tx-wl, Ie-sr-2tx-wl-4g-eu, Ie-sr-2tx-wl-4g-us-v | 2026-04-15 | 8.8 High |
| An authenticated remote attacker can execute arbitrary commands with root privileges on affected devices due to lack of improper sanitizing of user input in the Main Web Interface (endpoint tls_iotgen_setting). | ||||
| CVE-2025-64444 | 1 Sony | 1 Ncp-hg100 | 2026-04-15 | N/A |
| Improper neutralization of special elements used in an OS command ('OS Command Injection') issue exists in NCP-HG100 1.4.48.16 and earlier. If exploited, a remote attacker who has obtained the authentication information to log in to the management page of the product may execute an arbitrary OS command with root privileges. | ||||
| CVE-2024-3299 | 2026-04-15 | 7.8 High | ||
| Out-Of-Bounds Write, Use of Uninitialized Resource and Use-After-Free vulnerabilities exist in the file reading procedure in eDrawings from Release SOLIDWORKS 2023 through Release SOLIDWORKS 2024. These vulnerabilities could allow an attacker to execute arbitrary code while opening a specially crafted SLDDRW or SLDPRT file. NOTE: this vulnerability was SPLIT from CVE-2024-1847. | ||||
| CVE-2024-45252 | 1 Elsight | 1 Halo Firmware | 2026-04-15 | 9.8 Critical |
| Elsight – CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') | ||||
| CVE-2025-48204 | 2026-04-15 | 6.8 Medium | ||
| The ns_backup extension through 13.0.0 for TYPO3 allows command injection. | ||||