Export limit exceeded: 24527 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.

Search

Search Results (24527 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2024-55413 2026-04-15 7.8 High
A vulnerability exits in driver snxppamd.sys in SUNIX Parallel Driver x64 - 10.1.0.0, which allows low-privileged users to read and write arbitary i/o port via specially crafted IOCTL requests . This can be exploited for privilege escalation, code execution under high privileges, and information disclosure. These signed drivers can also be used to bypass the Microsoft driver-signing policy to deploy malicious code.
CVE-2021-4470 2 Tg8, Togrow 2 Tg8 Firewall, Tg8 Firewall 2026-04-15 N/A
TG8 Firewall contains a pre-authentication remote code execution vulnerability in the runphpcmd.php endpoint. The syscmd POST parameter is passed directly to a system command without validation and executed with root privileges. A remote, unauthenticated attacker can supply crafted values to execute arbitrary operating system commands as root, resulting in full device compromise.
CVE-2025-11900 1 Hgiga 1 Isherlock 2026-04-15 9.8 Critical
The iSherlock developed by HGiga has an OS Command Injection vulnerability, allowing unauthenticated remote attackers to inject arbitrary OS commands and execute them on the server.
CVE-2025-59729 1 Ffmpeg 1 Ffmpeg 2026-04-15 6.8 Medium
When parsing the header for a DHAV file, there's an integer underflow in offset calculation that leads to reading the duration from before the start of the allocated buffer. If we load a DHAV file that is larger than MAX_DURATION_BUFFER_SIZE bytes (0x100000) for example 0x101000 bytes, then at [0] we have size = 0x101000. At [1] we have end_buffer_size = 0x100000, and at [2] we have end_buffer_pos = 0x1000. The loop then scans backwards through the buffer looking for the dhav tag; when it is found, we'll calculate end_pos based on a 32-bit offset read from the buffer. There is subsequently a check [3] that end_pos is within the section of the file that has been copied into end_buffer, but it only correctly handles the cases where end_pos is before the start of the file or after the section copied into end_buffer, and not the case where end_pos is within the the file, but before the section copied into end_buffer. If we provide such an offset, (end_pos - end_buffer_pos) can underflow, resulting in the subsequent access at [4] occurring before the beginning of the allocation. We recommend upgrading to version 8.0 or beyond.
CVE-2024-53939 1 Victure 1 Rx1800 Firmware 2026-04-15 8.8 High
An issue was discovered in Victure RX1800 WiFi 6 Router (software EN_V1.0.0_r12_110933, hardware 1.0) devices. The /cgi-bin/luci/admin/opsw/Dual_freq_un_apple endpoint is vulnerable to command injection through the 2.4 GHz and 5 GHz name parameters, allowing an attacker to execute arbitrary commands on the device (with root-level permissions) via crafted input.
CVE-2025-24351 2026-04-15 8.8 High
A vulnerability in the “Remote Logging” functionality of the web application of ctrlX OS allows a remote authenticated (low-privileged) attacker to execute arbitrary OS commands in the context of user “root” via a crafted HTTP request.
CVE-2024-25002 2026-04-15 8.8 High
Command Injection in the diagnostics interface of the Bosch Network Synchronizer allows unauthorized users full access to the device.
CVE-2025-4422 1 Insyde 1 Insydeh2o 2026-04-15 8.2 High
The vulnerability was identified in the code developed specifically for Lenovo. Please visit "Lenovo Product Security Advisories and Announcements" webpage for more information about the vulnerability.  https://support.lenovo.com/us/en/product_security/home
CVE-2025-54994 2026-04-15 N/A
@akoskm/create-mcp-server-stdio is an MCP server starter kit that uses the StdioServerTransport. Prior to version 0.0.13, the MCP Server is written in a way that is vulnerable to command injection vulnerability attacks as part of some of its MCP Server tool definition and implementation. The MCP Server exposes the tool `which-app-on-port` which relies on Node.js child process API `exec` which is an unsafe and vulnerable API if concatenated with untrusted user input. Version 0.0.13 contains a fix for the issue.
CVE-2023-20513 2026-04-15 3.3 Low
An insufficient bounds check in PMFW (Power Management Firmware) may allow an attacker to utilize a malicious VF (virtualization function) to send a malformed message, potentially resulting in a denial of service.
CVE-2025-59732 1 Ffmpeg 1 Ffmpeg 2026-04-15 6.5 Medium
When decoding an OpenEXR file that uses DWAA or DWAB compression, there's an implicit assumption that the height and width are divisible by 8. If the height or width of the image is not divisible by 8, the copy loops at [0] and [1] will continue to write until the next multiple of 8. The buffer td->uncompressed_data is allocated in decode_block based on the precise height and width of the image, so the "rounded-up" multiple of 8 in the copy loop can exceed the buffer bounds, and the write block starting at [2] can corrupt following heap memory. We recommend upgrading to version 8.0 or beyond.
CVE-2024-13502 2026-04-15 N/A
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in Newtec/iDirect NTC2218, NTC2250, NTC2299 on Linux, PowerPC, ARM allows Local Code Inclusion.This issue affects NTC2218, NTC2250, NTC2299: from 1.0.1.1 through 2.2.6.19. The `commit_multicast` page used to configure multicasts in the modem's web administration interface uses improperly parses incoming data from the request before passing it to an `eval` statement in a bash script. This allows attackers to inject arbitrary shell commands.
CVE-2024-43653 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability  allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2024-32669 1 Samsung Open Source 1 Escargot 2026-04-15 5.3 Medium
Improper Input Validation vulnerability in Samsung Open Source escargot JavaScript engine allows Overflow Buffers. However, it occurs in the test code and does not include in the release. This issue affects escargot: 4.0.0.
CVE-2024-6333 1 Xerox 4 Altalink Firmware, Versalink Firmware, Workcentre Firmware and 1 more 2026-04-15 7.2 High
Authenticated Remote Code Execution in Altalink, Versalink & WorkCentre Products.
CVE-2013-10039 1 Gestioip 1 Gestioip 2026-04-15 N/A
A command injection vulnerability exists in GestioIP 3.0 commit ac67be and earlier in ip_checkhost.cgi. Crafted input to the 'ip' parameter allows attackers to execute arbitrary shell commands on the server via embedded base64-encoded payloads. Authentication may be required depending on deployment configuration.
CVE-2024-4301 2026-04-15 8.8 High
N-Reporter and N-Cloud, products of the N-Partner, have an OS Command Injection vulnerability. Remote attackers with normal user privilege can execute arbitrary system commands by manipulating user inputs on a specific page.
CVE-2024-38665 2026-04-15 8.4 High
Out-of-bounds write in some Intel(R) Graphics Drivers may allow an authenticated user to potentially enable escalation of privilege via local access.
CVE-2025-3626 2026-04-15 9.1 Critical
A remote attacker with administrator account can gain full control of the device due to improper neutralization of special elements used in an OS Command ('OS Command Injection') while uploading a config file via webUI.
CVE-2023-1082 2026-04-15 8.8 High
An remote attacker with low privileges can perform a command injection which can lead to root access.