Export limit exceeded: 24527 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.

Search

Search Results (24527 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2025-34095 2026-04-15 N/A
An OS command injection vulnerability exists in Mako Server versions 2.5 and 2.6, specifically within the tutorial interface provided by the examples/save.lsp endpoint. An unauthenticated attacker can send a crafted PUT request containing arbitrary Lua os.execute() code, which is then persisted on disk and triggered via a subsequent GET request to examples/manage.lsp. This allows remote command execution on the underlying operating system, impacting both Windows and Unix-based deployments.
CVE-2024-43657 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: High. However, the attacker will need a (low privilege) account to gain access to the action.exe CGI binary and upload the crafted firmware file, or convince a user with such access to upload it. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2024-43654 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root This issue affects all Iocharger AC EV charger models on a firmware version before 25010801. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2024-43651 2026-04-15 N/A
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC models before version 241207101 Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network connection serving the web interface is vulnerable (AV:N) and there are no additional measures to circumvent (AC:L) nor does the attack require special conditions to be present (AT:N). The attack requires authentication, but the level does not matter (PR:L), nor is user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H) and a compromised device can be used to potentially "pivot" into a network that should nopt be reachable (SC:L/SI:L/SA:H). Because this is an EV charger handing significant power, there is a potential safety impact (S:P). THe attack can be autometed (AU:Y).
CVE-2024-43650 2026-04-15 N/A
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root This issue affects  firmware versions before 24120701. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: The attack can be executed over any network connection serving the web interface (AV:N). There are no additional measures that need to be circumvented (AC:L) or attack preconditions (AT:N). THe attack is privileged, but the level does not matter (PR:L) and does not require user interaction (UI:N). Attack leads to full system compromised (VC:H/VI:H/VA:H) and compromised devices can be used to "pivot" to other networks that should be unreachable (SC:L/SI:L/SA:H). Because this an EV charger using high power, there is a potential safety impact (S:P). The attack can be automated (AU:Y).
CVE-2024-43649 2026-04-15 8.8 High
Authenticated command injection in the filename of a <redacted>.exe request leads to remote code execution as the root user. This issue affects Iocharger firmware for AC models before version 24120701. Likelihood: Moderate – This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all <redacted> fields. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a payload. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: This attack can be performed over any network conenction serving the web interfacr (AV:N), and there are not additional mitigating measures that need to be circumvented (AC:L) or other prerequisites (AT:N). The attack does require privileges, but the level does not matter (PR:L), there is no user interaction required (UI:N). The attack leeds to a full compromised of the charger (VC:H/VI:H/VA:H) and a compromised charger can be used to "pivot" to networks that should normally not be reachable (SC:L/SI:L/SA:H). Because this is an EV chargers with significant pwoer, there is a potential safety imp0act (S:P). THis attack can be automated (AU:Y).
CVE-2024-42029 1 Xdg 1 Desktop Portal Hyperland 2026-04-15 6.3 Medium
xdg-desktop-portal-hyprland (aka an XDG Desktop Portal backend for Hyprland) before 1.3.3 allows OS command execution, e.g., because single quotes are not used when sending a list of app IDs and titles via the environment.
CVE-2024-40641 1 Projectdiscovery 1 Nuclei 2026-04-15 7.4 High
Nuclei is a fast and customizable vulnerability scanner based on simple YAML based DSL. In affected versions it a way to execute code template without -code option and signature has been discovered. Some web applications inherit from Nuclei and allow users to edit and execute workflow files. In this case, users can execute arbitrary commands. (Although, as far as I know, most web applications use -t to execute). This issue has been addressed in version 3.3.0. Users are advised to upgrade. There are no known workarounds for this vulnerability.
CVE-2025-10774 1 Ruijie 2 Rg-uac 6000-e10, Rg-uac 6000-e10 Firmware 2026-04-15 4.7 Medium
A weakness has been identified in Ruijie 6000-E10 up to 2.4.3.6-20171117. This affects an unknown part of the file /view/vpn/autovpn/sub_commit.php. This manipulation of the argument key causes os command injection. It is possible to initiate the attack remotely. The exploit has been made available to the public and could be exploited. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-38512 1 Lenovo 1 Xclarity Controller 2026-04-15 7.2 High
A privilege escalation vulnerability was discovered in XCC that could allow an authenticated XCC user with elevated privileges to perform command injection via specially crafted IPMI commands.
CVE-2024-38511 2026-04-15 7.2 High
A privilege escalation vulnerability was discovered in an upload processing functionality of XCC that could allow an authenticated XCC user with elevated privileges to perform command injection via specially crafted file uploads.
CVE-2024-33222 1 Asus 1 Atszio Driver 2026-04-15 8.4 High
An issue in the component ATSZIO64.sys of ASUSTeK Computer Inc ASUS ATSZIO Driver v0.2.1.7 allows attackers to escalate privileges and execute arbitrary code via sending crafted IOCTL requests.
CVE-2024-33221 1 Asus 1 Bios Flash Driver 2026-04-15 7.8 High
An issue in the component AsusBSItf.sys of ASUSTeK Computer Inc ASUS BIOS Flash Driver v3.2.12.0 allows attackers to escalate privileges and execute arbitrary code via sending crafted IOCTL requests.
CVE-2024-3298 2026-04-15 7.8 High
Out-Of-Bounds Write and Type Confusion vulnerabilities exist in the file reading procedure in eDrawings from Release SOLIDWORKS 2023 through Release SOLIDWORKS 2024. These vulnerabilities could allow an attacker to execute arbitrary code while opening a specially crafted DWG or DXF. NOTE: this vulnerability was SPLIT from CVE-2024-1847.
CVE-2023-51452 2026-04-15 3 Low
A Improper Input Validation issue affecting the v2_sdk_service running on a set of DJI drone devices on the port 10000 could allow an attacker to cause a crash of the service through a crafted payload triggering a missing input size check in the pull_file_v2_proc function implemented in the libv2_sdk.so library used by the dji_vtwo_sdk binary implementing the service, compromising it in a term of availability and producing a denial-of-service attack. Affected models are Mavic 3 Pro until v01.01.0300, Mavic 3 until v01.00.1200, Mavic 3 Classic until v01.00.0500, Mavic 3 Enterprise until v07.01.10.03, Matrice 300 until v57.00.01.00, Matrice M30 until v07.01.0022 and Mini 3 Pro until v01.00.0620.
CVE-2024-28750 1 Ifm 2 Smart Plc Ac14xx Firmware, Smart Plc Ac4xxs Firmware 2026-04-15 7.2 High
A remote attacker with high privileges may use a deleting file function to inject OS commands.
CVE-2025-10619 1 Sequa-ai 1 Sequa-mcp 2026-04-15 6.3 Medium
A vulnerability was detected in sequa-ai sequa-mcp up to 1.0.13. This affects the function redirectToAuthorization of the file src/helpers/node-oauth-client-provider.ts of the component OAuth Server Discovery. Performing manipulation results in os command injection. Remote exploitation of the attack is possible. The exploit is now public and may be used. Upgrading to version 1.0.14 is able to mitigate this issue. The patch is named e569815854166db5f71c2e722408f8957fb9e804. It is recommended to upgrade the affected component. The vendor explains: "We only promote that mcp server with our own URLs that have a valid response, but yes if someone would use it with a non sequa url, this is a valid attack vector. We have released a new version (1.0.14) that fixes this and validates that only URLs can be opened."
CVE-2025-9976 1 Dassault 1 Station Launcher App 2026-04-15 9 Critical
An OS Command Injection vulnerability affecting Station Launcher App in 3DEXPERIENCE platform from Release 3DEXPERIENCE R2022x through Release 3DEXPERIENCE R2025x could allow an attacker to execute arbitrary code on the user's machine.
CVE-2025-30015 2026-04-15 4.1 Medium
Due to incorrect memory address handling in ABAP SQL of SAP NetWeaver and ABAP Platform (Application Server ABAP), an authenticated attacker with high privileges could execute certain forms of SQL queries leading to manipulation of content in the output variable. This vulnerability has a low impact on the confidentiality, integrity and the availability of the application.
CVE-2024-24899 2026-04-15 7.2 High
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in openEuler aops-zeus on Linux allows Command Injection. This vulnerability is associated with program files https://gitee.Com/openeuler/aops-zeus/blob/master/zeus/conf/constant.Py. This issue affects aops-zeus: from 1.2.0 through 1.4.0.